Electrical Engineering

AC Network and Theorems Experimental Set up 9504

SALIENT FEATURES : AC Network & Theorems Experimental Set – up, is versatile and useful educational training equipment for both the electrical & electronic branches of engineering? It is one of the many specialised training equipments from the house of “Adtron – the training people, who have over a decade of experience in manufacturing educational…

Electrical Machine Trainer (EMT1)

SALIENT FEATURES TECHNICAL SPECIFICATIONS: Suitable for demonstrating the construction and functioning of different type of D.C. machines and A.C. machines (1 phase and 3 phase). The trainer made of well machined M.S. / Bakelite 12 mm thick base plate. The plate fitted on M.S “C “ channel of 70X40X6mm. The bearing housing spilt type and…

Power Measurement Using Two Wattmeter Method 9522

SALIENT FEATURES :             ADTRON’s Power Measurement by Two Wattmeter Method Model 9522 is a versatile, self contained and standalone unit. It helps the students in understanding the different parameters like Line Voltage, Line Current, Phase Current, Phase voltage and their relationship in 3 Phase Star or Delta connected supply. It demonstrated the use of…

Parallel Operation of Two Single Phase Transformers 9521

SALIENT FEATURES :              ADTRON’s Parallel operation of Two Single Phase Transformers Model 9521 is a versatile, self contained and standalone unit. It helps the students in understanding the concept of connecting two transformers in parallel, Polarity of transformers and loading of transformers. The unit consists of two identical single phase transformers of 1 KVA…

Sumpner’s Test Using Two Single Phase Transformers 9520

SALIENT FEATURES :         ADTRON’S Sumpner’s Test using Two Single phase Transformers, Model 9520 is a versatile and self contained trainer kit useful for conducting Sumpner’s Test experiment using two single phase transformers. The trainer kit is useful for the conducting Sumpner’s test experiment and polarity phenomenon. The unit is housed in an elegant metal…

Single Phase Transformer Lab MODEL – 9509

Single Phase Transformer Lab is a very versatile and useful training system for the Electrical laboratories of Engineering, Polytechnic and vocational Institutes.  It helps in understanding the basic concepts and functioning of a Single Phase Transformer. The unit helps in understanding the concepts of Polarity, Turns Ratio, Transformation Ratio, Iron Loss, Copper Loss, Efficiency etc….

Three Phase Transformer Lab MODEL – 9510

Three Phase Transformer Lab is versatile and useful training system for the Electrical Laboratories of Engineering, Polytechnics and Vocational courses. The lab consists of a Three Phase Transformer with its Primary and Secondary connections brought out on panel, multi function meter to measure Voltage, Current, Watts, PF, etc, Three Phase Mains MCB, etc  all housed…

Sub – Station Protection and Operation Control Panel 9508

SALIENT FEATURES : ADTRON’S Sub – Station Protection & Operation Control Panel is a very versatile and useful electrical training system. It provides various experiments on Sub – Station Operation & Protection. The complete system developed is simulator based for the study of a sub – station having SHORT / MEDIUM / LONG Transmission Line as…

Feeder and Motor Protection Panel 9507A

SALIENT FEATURES :              Adtron’s Feeder & Motor Protection Panel is a very versatile and useful electrical training system. It provides various experiments on Feeder & Motor Protection. The complete system consists of a three phase feeder with bus bar, output line meters, indicating lamps, contactors / relay, protection relay and other necessary accessories for…

Transmission Line Simulator with Protection System 9506

SALIENT FEATURES :             Adtron’s transmission line simulator with protection system consists of a miniature transmission line arranged to represent 3 phase AC long transmission line having ACSR conductors 37/0.146 with spacing 6.7 meters to transmit the power of 90 MW at 0.9 p.f. The panel consists of the following: 1.      Auto Transformer ( 01…

Transformer with Protection Panel ( 1 f ) 9505B

 SALIENT FEATURES : The single phase transformer protection panel consists of various items and equipments for typical protection schemes for single phase transformer. The panel helps the students to study and clearly understand the protection schemes under actual load condition. The following items / equipments are provided. 1.      Transformer             :           Single phase transformer.           Primary                      :          415…

Transformer with Protection Panel ( 3 f ) 9505A

SALIENT FEATURES : ADTRON’S Transformer with Protection Panel is a very versatile and useful electrical training system. It provides a complete set up for experiments on transformer and its protection. The complete system consists of a three phase transformer, meters, contractors / relays, CT’s and other necessary accessories for independent study. Necessary non – destructive fault…

Measurement of High Voltage and High Current Using CT & PT 9502

SALIENT FEATURES : The Adtron’s Model 9502 Measurement of High Voltage and High Current trainer kit is a versatile and dedicated trainer kit which helps the students to understand the principle and use of CT and PT. The trainer kit consists of a high voltage source, a high current source and required ammeters and voltmeters….

Three Phase Measurement System ( Star / Delta ) 9501

SALIENT FEATURES : Adtron’s Three Phase Measurement System is a self contained, stand – alone unit useful in the study of measurement of various paraments in three phase star and delta configuration. The unit consists of low voltage isolated, protected 3 phase supply with full instrumentation and three variable R, L and C loads. The unit is…

Constant M – Type Band Pass Filter 8018

SALIENT FEATURES : *          Dedicated trainer board for each filter circuit. *          Completely self contained stand – alone unit. *          Demonstrates the principle & working of a passive constant M – type band pass filter circuit. *          Study the attenuation & phase characteristics of the filter circuit. *          Multi – coloured test points to connect…