Measurement of Speed Using Inductive Pick – Up Transducer ( Digital ) 3015

Categories: Instrumentation

3015

SALIENT FEATURES :

 

ADTRON’S Measurement of speed using Inductive transducer trainer is a versatile stand alone unit useful in the study and demonstration of the principle and working of a speed measuring system using Inductive transducer. The trainer consists of the complete instrumentation viz., pulse generator, counter circuit, decoder, driver and seven segment displays to indicate the speed in revolutions per minute (R.P.M). It also has a motor speed controller. The motor unit with inductive transducer is separately housed. The main trainer is housed in a specially designed users friendly elegant powder coated metal cabinet with an intelligently designed circuit layout on imported acrylic front panel.

TECHNICAL SPECIFICATIONS

MOTOR UNIT :

Motor                                      :           Specially designed bi-directional, permanent magnet armature controlled DC motor.

Power                                      :            6W.

Speed                                       :            3500 R.P.M Max.

Voltage                                   :            12V DC.

Torque                                   :             0.3 Kg. cm2

Mounting                             :             Motor mounted with wheel and Inductive transducer.

Connector                           :             Special connector with wires to connect motor unit to measuring unit.

MAIN MEASURING UNIT :

Parameter Measured          :             Speed in R.P.M.

Speed Control                        :             Bulit – in solid state speed controller voltage based.

System Range                        :             5000 RPM Max.

Instrumentation                  :             Pulse generator, counter, decoder, driver.

Readout                                   :             4 digit digital readout 0.5” Red.

Controls                                   :             a. Speed control.

                                                                   b. Mains ON / OFF.

Connector                               :             Facility for connecting the motor unit.

Test Points                              :             Multi – coloured test points are provided at various stages in the circuit to observe waveforms and voltages.

Indicator                                 :             Mains ON/OFF.

Power Requirements          :             230V,± 10% AC, 50Hz 1 phase.

Panel Size                                 :             10” x 13”.

Standard Accessories         :             Detailed Instruction Manual.