Electrical Engineering

AC Network and Theorems Experimental Set up 9504

SALIENT FEATURES :

AC Network & Theorems Experimental Set – up, is versatile and useful educational training equipment for both the electrical & electronic branches of engineering? It is one of the many specialised training equipments from the house of “Adtron – the training people, who have over a decade of experience in manufacturing educational training equipments and teaching aids.

            AC Network & Theorems Experimental Set – up, is useful for the study and practical verification of Electrical / Electronic Networks & Theorems with AC supply by using R, L & C parameters (elements). The experimental set – up is compact and self – contained and comes with a comprehensive instruction manual with explains all relevant information with experiments in simple and easy to understand terms. The students can be led step by step for verification, which will promote better subject understanding capabilities in the future.

*         Ideal tool for learning basics of theorems applied to AC Network.

*         Mains operated, self – contained system.

*         Power supply provided with phase shift device to obtain desired phase difference.

*         Proper safety precautions provided.

*         Built – in precision RLC components and metes, to provide data verification along with power factor measurement.

The following experiments can be performed using the built – in dedicated theorems circuit with RLC components.

*         Super Position Theorem.

*         Thevenin’s Theorem.

*         Maximum Power Transfer Theorem.

*         Kirchoff’s Current Law ( KCL ).

*         Kirchoff’s Voltage Law ( KVL ).

Technical Specifications

*         R, L & C Parameters ( Elements ) in Branches :

a.         Variable resistance upto 100 ohms / 2.5A in incremental steps     :           01 Nos.

b.         Variable inductance upto 600 mH / 2A in incremental steps          :           03 Nos.

c.         Variable capacitance upto 50 f / 250V in incremental   steps       :           04 Nos.

( capacitance are fitted with discharge resistors for protection ).

Note :              The above elements are incorporated in the various dedicated theorems set – up as per requirements of the theorems.

3.         Power Supply :

a.         Dual Power Supply Source :

Input                 :           230 V AC, 50 Hz, single phase.

Output              :           Dual separate output as follows :

i.          0 – 240 V / 5A, 50 Hz, single phase AC continuous adjustable

ii.          0 – 240 V / 5A, 50 Hz, single phase AC continuous adjustable

Protection         :           MCB switch for both output and separate indicating lamps for mains ON.

b.         A separate voltage source with facility for phase shifting of voltage is provided.

*             Metering & Instrumentation :

Sr.

No.

Meter

Type

Range

Location

Type

Qty

1.

Ammeter

AC

Analog

AC

0 – 2.5 Amp

AC

Source & Branches

Portable

Type

07

Nos.

2.

Voltmeter

AC

Analog

AC

0 – 250 V

AC

Source & other locations

96 x 96

Panel Type

04

Nos.

3.

Wattmeter

AC

Analog AC

Dynamometer Type

250 V

2.5 Amp AC

Load &

Branches

96 x 96

Panel Type

03

Nos.

4.

PF Meter

AC

Analog AC

Dynamometer Type

250 V

2.5 Amp AC

Source &

Branches

96 x 96

Panel Type

05

Nos.

Note :

a.

All analog ammeters are of + 0.5 % accuracy, class 0.5 precision grade type.

b.

All other analog meter are of + 1.0 % accuracy, class 1.0 grade type.

c.

All analog meters are permanently connected in the circuits as per the theorem requirements.

*          All the networks & theorems are arranged with separate & required meters having following major aspects :

a.         The circuits are arranged separately for verification of respective theorems.

b.         The front panel is provided with proper mimic including required meters, test points and proper terminations of the R, L & C parameters.

c.         Facility of detecting reverse flow of current during verification of Super Position Theorem is provided.

d.         The circuits are assembled in proper panel type metal enclosure.

*          Theorems Networks :

a.         Superpositions Theorem is arranged with R, L & C parameters ( elements ) along with :

i.          P. F. meters to measure phase difference in terms of COS .

ii.          Facility of detecting reverse flow of current in that branch.

b.         Thevenin’s Theorem is supplied with separate :

i.          Original network containing R, L & C elements.

ii.          Equivalent voltage source with desired phase shift for VTH.

c.         Maximum Power Transfer Theorem in AC supply is assembled with :

i.          Wattmeter, Ammeter & Voltmeter permanently connected in circuit.

Note :

             With suitable precautions and proper values of R, L & C elements Super Position Theorem’s verification network can be used for verification of :

1.         Kirchoff’s Current Law ( KCL ).

2.         Kirchoff’s Voltage Law ( KVL ).

*          Controls Terminations & Protection :

1.         Capacitors are fitted with discharge resistors.

2.         Supply line inputs is protected by MCB.

3.         Necessary terminations, switches and control are provided in each circuit as per the requirements for proper operation.

4.         Connections by 4 mm colour coded binding posts.

*          A detailed, comprehensive & well illustrated instruction manual is provided.

Being an experimental set up, the importance is given to the understanding of the various theorems by giving the facility, to perform the experiment at different sets of parameters, where by the tolerance level between the theoretical & practical results will be in the range of 20 %, as the values of L and even to some extent C will change under different conditions of voltage, current and temperature.

Electrical Machine Trainer (EMT1)

SALIENT FEATURES TECHNICAL SPECIFICATIONS: Suitable for demonstrating the construction and functioning of different type of D.C. machines and A.C. machines (1 phase and 3 phase). The trainer made of well machined M.S. / Bakelite 12 mm thick base plate. The plate fitted on M.S “C “ channel of 70X40X6mm. The bearing housing spilt type and prepared from aluminum casting. Trainer includes Following 6 Machines & Control Panel.

1) MACHINE NO.1 D.C.MACHINE Consisting of shunt, series and inter pole for two poles. Series field and Interpole winding are interconnected. Working voltage – 110 V DC Capacity – 300 Watt Connections – All field and armature winding terminals are brought out on Terminal plate using banana terminals

2) MACHINE NO.2 3 PHASE SQUIRREL CAGE INDUCTION MOTOR Working voltage – 110V 3 phase, 50 Hz Capacity – 300 watt, R. P. M. – 1400 Connections – six terminals are provided on terminal plate using banana terminals.

3) MACHINE NO.3 A.C. SINGLE PHASE CAPACITOR START MOTOR With centrifugal switch arrangement working voltage – 110V, 50 Hz Capacity – 300 watt R.P.M. – 1440 Connections – 2 terminals of starting winding and 2 terminals of centrifugal switch and 2 terminals of capacitor, two terminals of main winding ,total of 8 terminals brought out on terminal plate using banana terminals.

4) MACHINE NO. 4 3 PHASE SLIPRING INDUCTION MOTOR Working voltage – 110v, 50 Hz Capacity – 300watt R.P.M. – 1440 Starter – suitable rotor resistance starter. Connections – Terminals are brought on terminal plate by banana terminal.

5) MACHINE NO. 5 3 PHASE ALTERNATOR Type – Rotating field type Rotor – Salient pole type with field coils Output Voltage – 110V, 3 Phase, 50 Hz R.P.M. – 1500  4) MACHINE NO. 4 3 PHASE SLIPRING INDUCTION MOTOR Working voltage – 110v, 50 Hz Capacity – 300watt R.P.M. – 1440 Starter – suitable rotor resistance starter. Connections – Terminals are brought on terminal plate by banana terminal.

5) MACHINE NO. 5 3 PHASE ALTERNATOR Type – Rotating field type Rotor – Salient pole type with field coils Output Voltage – 110V, 3 Phase, 50 Hz R.P.M. – 1500

6) MACHINE NO. 6 3 PHASE ROTARY CONVERTOR AND INVERTOR Consisting of field pole and field winding working voltage – 110V, Capacity – 300WAC/DC Suitable terminals are brought on terminals plate with proper banana terminals.

7) POWER SUPPLY PANEL BOARD 3 PHASE 110V, 50 Hz AC Panel is made of M.S steel cabinet and powder coated Back side of panel board provided with door & locking arrangement Front panel is mounted with following Digital voltmeter 0-500V A.C. (48x96mm) for input Digital voltmeter 0-150V A.C.(48x96mm) for output Digital ammeter 0-5AMP A.C. (48x96mm) for input Digital ammeter 0-5AMP A.C (48x96mm) for output Incoming mains three phase 415v ,50HZ ,A.C. Incoming 4 pole M.C.B. 10A 415V 25mm LED indicating lamp for incoming & outgoing R,Y,B, supply Banana terminals for incoming 3 phase 4 wire & for outgoing 3 phase 4 wire with colour code All accessories connected internally by proper gauge & ISI multi-strand wire with proper termination of lugs

8) POWER SUPPLY PANEL BOARD SINGLE PHASE & D.C 110v AC/DC Panel made of M.S steel cabinet and powder coated Front panel mounted with following accessories Back side of the panel board provided with door & locking arrangement Digital voltmeter A.C. 0-300v (48x96mm) for incoming supply Digital ammeter A.C. 0-5A (48x96mm) for incoming supply Digital voltmeter A.C.0-150v (48x96mm) for outgoing Digital ammeter A.C.0-5A (48x96mm) for outgoing Digital Voltmeter D.C. 0-150v (48x96mm) for outgoing Digital ammeter D.C.0-5A (48x96mm) for outgoing Incoming A.C. 230v ,50HZ 2 pole 10A M.C.B. for incoming Colour code banana terminals for incoming AC & outgoing DC All accessories connected internally by proper gauge ISI multi-stand wires with proper termination of lugs 25 mm led indicating lamp for incoming & outgoing supply

9) LOAD AND OTHER ACCESSORIES Resistive, Inductive and Capacitive load variable in steps for alternator & DC generator loading Change over switch for synchronous motor experiment Following Experiments can be performed on the Electrical Machine Trainer

1. D.C. series motor

2. D.C. shunt motor

3. D.C. compound motor

4. D.C. series generator

5. D.C. shunt generator

6. D. C. compound generator

7. Separately excited DC generator

8. AC series motor

9. Single phase AC repulsion motor

10. Rotary convertor

11. Rotary inverter

12. 3 phase squirrel cage induction motor

13. 3 phase slip ring induction motor

14. 3 phase synchronous motor

15. 3 phase alternator rotating field type

16. 3 phase alternator rotating armature type

17. Single phase alternator rotating field type

18. Single phase capacitor start induction motor

SPECIFICATIONS ARE SUBJECT TO CHANGE DUE TO CONSTANT DEVELOPMENTS WITHOUT ANY PRIOR NOTICE

Power Measurement Using Two Wattmeter Method 9522

SALIENT FEATURES :

            ADTRON’s Power Measurement by Two Wattmeter Method Model 9522 is a versatile, self contained and standalone unit. It helps the students in understanding the different parameters like Line Voltage, Line Current, Phase Current, Phase voltage and their relationship in 3 Phase Star or Delta connected supply. It demonstrated the use of wattmeters in measuring power in a 3 phase circuit, study the power flow in three phase system and calculate Active, Reactive and Apparent power. The unit consists of various meters, resistive and Inductive load, etc all housed in an elegant powder coated metal cabinet with a well spread intelligently designed layout on front panel. The unit is accompanied with a comprehensive Instruction manual complete with theory, operating details, connection drawings and observation tables.

 TECHNICAL SPECIFICATIONS

 *     INPUT SUPPLY                     :           3 Phase, 440V, 50 Hz, AC

 Meters ( All meters are 96 x 96 / 72 x 72 size Analog meters )

 1.         Voltmeter                          :           0 – 500V AC         –           1 Nos

 2.         Ammeter                           :           0 – 1A AC                –           1 Nos

 3.        Wattmeter                          :           0 – 500W                –           2 Nos

 Controls

 Mains                                                :           10 A, 3 Phase MCB ( PTN )

 Indicators                                       :           Colour coded R,Y,B Indicator

 Load

 1.         Resistive                             :           3 Nos Lamp load 1 for each phase.

2.         Inductive                            :           3 Nos Inductive Load 1 for each phase.

 Experiments

 1.         Study and measure Line Current, Line voltage, Phase current, Phase voltage, etc in a 3 Phase Star or Delta connected system.

 2.         Study and measure the Power factor in a three phase star / delta connected circuit.

 3.         Measurement of Active, Reactive and Apparent power in a three phase circuit using 2 wattmeter method.

Parallel Operation of Two Single Phase Transformers 9521

SALIENT FEATURES :

             ADTRON’s Parallel operation of Two Single Phase Transformers Model 9521 is a versatile, self contained and standalone unit. It helps the students in understanding the concept of connecting two transformers in parallel, Polarity of transformers and loading of transformers. The unit consists of two identical single phase transformers of 1 KVA rating each, voltmeters, Ammeters, MCB, etc all housed in an elegant metal cabinet with a well spread intelligently designed panel layout on the front panel. The unit is accompanied with a comprehensive Instruction Manual complete with theory, operating details, connection drawings and observation tables.

 TECHNICAL SPECIFICATION

 *          Input Supply                                      :           1 Phase, 230V, 50 Hz AC

 *          Experimental Transformer          :           01 nos

             Primary                                                :           0 – 230V

             Secondary                                           :           0 – 200 – 230V

             Current                                                 :           5A

             Rating                                                    :           1 KVA

 *          Meters                                                :           All meters of 96 x 96 / 72 x 72 size Analog meters

              1. Voltmeter                                      :           0 – 500 V AC     :           02 Nos

              2. Ammeter                                       :           0 – 10 A AC         :           02 Nos

*          Controls

              Mains                                                   :           10A, 1Phase MCB

 *          Indicators                                          :           For Input Supply

 *          Load                

            1. Internal                                           :           Resistive ( Lamp ) Load

            2. External                                          :           Provision for connecting external load.

 *          Experiments

 1.         Study and conduct the Polarity test on two single phase transformer.

2.         Study and conduct parallel operation of two single phase transformers under equal voltage ratio.

3.         Study and conduct parallel operation of two single phase transformers under unequal voltage ratio

Sumpner’s Test Using Two Single Phase Transformers 9520

SALIENT FEATURES :

        ADTRON’S Sumpner’s Test using Two Single phase Transformers, Model 9520 is a versatile and self contained trainer kit useful for conducting Sumpner’s Test experiment using two single phase transformers. The trainer kit is useful for the conducting Sumpner’s test experiment and polarity phenomenon. The unit is housed in an elegant metal cabinet with a well spread intelligently deigned layout on the front panel. It is strongly supported by a comprehensive instruction manual complete with theory operating details and procedure.

 TECHNICAL SPECIFICATION

 A)         EXPERIMENTAL TRANSFORMER

                Rating                                :           1KVA

               Primary Voltage            :           0 – 125V, 0 – 125V

               Secondary Voltage       :           0 – 125V, 0 – 125V

               Rated Current                 :           5A.

 B)         METERS (ALL METERS 72 X 72 SQUARE and 96 x 96 Square )

                Voltmeter                       :           0 – 100V AC, 1 Nos

                Voltmeter                       :           0 – 300V AC, 1 Nos

                Ammeter                        :           0 – 10A AC, 1 Nos        

                Ammeter                        :           0 – 1A AC, 1 Nos

               Wattmeter                      :            0 – 100W, 1 Nos

               Wattmeter                      :            0 – 1000W, 1 Nos

 C)         AUTO TRANSFORMER

               Primary                           :           230V

               Secondary                      :           0 – 270V

               Current                            :           10A

 D)         Temperature Indicator  :           Display to indicate the rise in temperature of transformer.

 E)         CONTROLS

                Mains                               :           MCB

                Variac                              :          ON / OFF Switch

 F)         EXPERIMENTS

 *          Determination of Efficiency and Voltage Regulation of Two Single Ohase Transformers.

*          Study the polarity test using two single phase transformers.

*          Study of Sumpner’s Test by              

             i.          Open circuit  and

            ii.          Short circuit test.

Single Phase Transformer Lab MODEL – 9509

Single Phase Transformer Lab is a very versatile and useful training system for the Electrical laboratories of Engineering, Polytechnic and vocational Institutes.  It helps in understanding the basic concepts and functioning of a Single Phase Transformer. The unit helps in understanding the concepts of Polarity, Turns Ratio, Transformation Ratio, Iron Loss, Copper Loss, Efficiency etc. of a Single Phase Transformer. The unit consists of a variac, meters, transformer, etc, all housed in a elegant metal cabinet with a well spread intelligently designed circuit layout on front panel. A comprehensive Instruction manual compete with Theory and operating details is provided.

 

Salient Features

 

*          Inbuilt Single Phase Variac

*          Single phase 1KVA Transformer

*          Voltmeter, Ammeter and Wattmeter provided on panel for measurements

*          Facility for connecting external load.

*          Facility to study step up, step down and Isolation transformer.

 

Technical Specifications

 

1.         Study Transformer

 

Type                             :           Single Phase

Primary                         :           0 – 125V, 0 – 125V

Secondary                    :           0 – 125V, 0 – 125V

Current                          :           4A max

Rating                           :           1 KVA

 

2.         Variac

 

Type                             :           Single Phase

Output                          :           0 – 270V

Current                          :           5A max

 

3.         Voltmeters

Type                             :           Analog

Range                           :           1.         0 – 300V AC ( MI ) – 02 Nos

2.         0 – 50V AC ( MI ) – 01 Nos

Size                              :           96 x 96 Square

4.         Ammeters

 

Type                             :           Analog

Range                           :           1.         0 – 5A AC ( MI ) – 02 Nos

2.         0 – 1A AC ( MI ) – 01 Nos

Size                              :           96 x 96 Square

 

5.         Wattmeters

 

Type                             :           Analog

Range                           :           1.         0 – 100W

2.         0 – 1000W

Size                              :           96 x 96 Square

 

6.         Mains ON / OFF            :           MCB 6A

 

7.         Experiments

1.         Study and calculate the Turns Ratio of a Single Phase Transformer.

2.         Study and calculate the Iron and Copper losses of a Single Phase Transformer.

3.         Study and observe the concept of polarity.

4.         Study and calculate the Transformation Ratio of a Single Phase Transformer.

5.         Study and calculate the Efficiency of a Single Phase Transformer.

 

OPTIONAL :

*          Resistive Load of capacity 1KVA.

 

Three Phase Transformer Lab MODEL – 9510

R_10-1Three Phase Transformer Lab is versatile and useful training system for the Electrical Laboratories of Engineering, Polytechnics and Vocational courses. The lab consists of a Three Phase Transformer with its Primary and Secondary connections brought out on panel, multi function meter to measure Voltage, Current, Watts, PF, etc, Three Phase Mains MCB, etc  all housed in a metal cabinet with a well spread intelligently designed circuit layout on the front panel. A Comprehensive Instruction manual complete with theory and operating details is provided.

 

Salient Features

 

ü         Three Phase 1 KVA Transformer.

ü         Multi-Function Meter to measure Voltage, Current, Watts, PF, etc.

ü         Study of Star – Star, Star – Delta, Delta – Star, Delta – Delta configuration of Three Phase

ü         Experiments like Polarity, Losses, Efficiency, Voltage Regulation, etc can be performed.

 

Technical Specifications

 

1.         Study Transformer

Type                            :           Three Phase

Primary                       :           415V

Secondary                  :           230V

Current                        :           4A

Rating                          :           1 KVA

 

2.         Multi-Function Meter

Type                            :           Three Phase, Digital

Circuit                          :           DSP based

Parameters                 :           Line to neutral Voltages, Line to Line Voltages, Current, Frequency,

Active Power, Reactive Power, Apparent Power, Active Energy, Reactive Energy, Apparent                                                                                Energy and Power Factor.

Display                        :           Five row 4-Digit Bright Red Seven Segment Display

Measurement             :           True RMS Measurement

 

 

3.         Mains ON/OFF           :           3 Ph MCB 6A

 

4.         Indicators                    :           Three Phase Input supply

 

5.         Protection                    :           Fuse Protection at Input Supply for 3 f.

 

7.         Experiments

 

1.         Study and measure the Primary and Secondary Voltages of a Star – Star, Star – Delta,

Delta – Star, Delta – Delta connected transformer.

2.         Study of Open circuit Test on a Three Phase Transformer.

3.         Study of Short circuit Test of a Three Phase Transformer.

4.         Study of Load Test of a Three Phase Transformer.

5.         Determine the Voltage Regulation of a Three Phase Transformer.

6.         Determine the Efficiency of a Three Phase Transformer.

OPTIONAL :

*         Three Phase Variac 10A

*         Three Phase Resistive Load 1 KVA

 

Sub – Station Protection and Operation Control Panel 9508

SALIENT FEATURES :

ADTRON’S Sub – Station Protection & Operation Control Panel is a very versatile and useful electrical training system. It provides various experiments on Sub – Station Operation & Protection. The complete system developed is simulator based for the study of a sub – station having SHORT / MEDIUM / LONG Transmission Line as incoming line to the sub station. Necessary non – destructive fault simulation are provided. The panel will consists of various components and accessories as follows:

*     TRANSMISSION LINE :

A Transmission line of 80 – 400 Km long will be represented by equipment R, L & C parameters divided in five sections with inter connecting switch / links between the sections for 3 phase, 415 V, 50 Hz operation.

*     METERING :

Various meters of 96 mm x 96 mm square, of good accuracy are provided as follows:

i.      Voltmeter with selector switch at sending end and receiving end.

         Range 0 – 500 V AC : 02 Nos.

ii.     Ammeter in phase for measuring.

         a.      Line current under load condition 0 – 5 Amp : 01 Nos.

         b.      No load current 0 – 1 Amp with bypass SC link : 01 Nos.

*     PANEL WITH ACCESSORIES :

Necessary meters as mentioned above, various MCB’s indicating lamps, contactors / relays along with selected position protection scheme components ( selected from the options provided ) are mounted on a proper panel with necessary wiring. The protection scheme will consists of special protective relays with their connecting terminals brought out on the panel in the form of additional sockets for testing calibration purpose. Input and output terminals for connections of supply and load through meters and relays are provided.

*     PROTECTION RELAYS :

*     P. F. PROTECTION RELAY :

Connect at receiving end to check and adjust the PF of the transmission line by using mP based PF controller relay along with capacitor shunt back six state, each step of equal magnitude.

*     DISTANCE PROTECTION RELAY :

By using numerical distance relay with 5 zones of protection each for respective section in transmission line simulator. The relay will also give full options for the protection O.L / O.V / U.V / Directional E.F.

*     TAP CONTROL CIRCUIT :

To adjust the output voltage from the bus bar, it is necessary to operate tap changes of transformer. A dummy arrangement will be worked out to shown the operation of tap changer through the relay and auxiliary circuit.

*     FAULT SIMULATION :

1.      E.F. in each section one at a time will be created to observe the operation of protection relays.

2.      Contactors will be provided at both receiving and sending end.

3.      The arrangement for indicating the faulty section is by indication lamp when the relay operates for that section.

*     INSTRUCTION MANUAL  :

A detailed instructional / operational manual with details and circuit drawing is provided for students and teachers.